Widely used in limited power control or signalling applications such as doorbell transformers, motor actuators and ignition systems. Foot and / or hub mounted transformers ranging from 20 to 375 V and are available with single or dual threaded hubs. UL listed / UL recognised component provided with circuit breaker and pigtail wires

Filter

Functional Devices Class 2 transformers convert high-voltage electricity to low-voltage electricity. They are useful in electronics, lighting and power distribution systems. They can provide a... Read More

FUNCTIONAL DEVICES INC / RIB -

Class 2 Transformers with Automatic Short Circuit Protection

StyleModelDepthEnclosure RatingEnclosure TypeHeightInput VoltageMountingVa RatingWidthPrice (inc. GST)
ATR20VA0011.88"Not RatedIndoor2.63"120 VACFoot or 1/2" NPT Hub202.13" SGD 31.69
BTR20VA0031.88"Not RatedIndoor2.63"24 VACFoot or 1/2" NPT Hub202.13" SGD 28.26
CTR20VA0071.88"Not RatedIndoor2.63"277 VACFoot or 1/2" NPT Hub202.13" SGD 26.69
DTR20VA0041.89"Not RatedIndoor2.62"120/208/240/277 VACFoot or Dual 1/2" NPT Hub202.31" SGD 38.28
ETR20VA0021.902"Not RatedIndoor2.616"208 VACFoot or Dual 1/2" NPT Hub202.296" SGD 28.48
FTR40VA0012.19"Not RatedIndoor2.88"120 VACFoot or 1/2" NPT Hub402.69" SGD 36.99
GTR40VA0032.19"Not RatedIndoor2.88"24 VACFoot or 1/2" NPT Hub402.69" SGD 35.10
HTR40VA0152.19"Not RatedIndoor2.88"120/208/240 VACFoot or 1/2" NPT Hub402.69" SGD 47.69
ITR40VA0042.19"Not RatedIndoor2.88"120/208/240/277 VACFoot or Dual 1/2" NPT Hub402.69" SGD 45.01
JTR40VA0402.171"Not RatedIndoor2.89"120/208/240 VACFoot or 1/2" NPT Hub402.728" SGD 40.01
KTR40VA0022.177"Not RatedIndoor2.886"120 VACFoot or Dual 1/2" NPT Hub402.634" SGD 38.87
LPSH40AB104.5"Nema 1Enclosed4.5"120 VACMulti405.43" SGD 188.40
MPSH40AB10-EXT24.5"Nema 1Enclosed4.5"120 VACMulti405.43" SGD 239.72
NPSH100A100AB104.5"Nema 1Enclosed4.5"120 VACMulti1008.62" SGD 378.75
OPSH200A4.5"Nema 1Enclosed4.5"120/240/277/347/480 VACMulti405.44" SGD 782.84
PTR40VA001US4.25"Not RatedIndoor3.25"120 VACFoot or 1/2" NPT Hub402.5" SGD 53.01
FUNCTIONAL DEVICES INC / RIB -

Class 2 Transformers with Secondary Circuit Protection

StyleModelDepthEnclosure RatingEnclosure TypeHeightInput VoltageItemMountingOutput VoltagePrice (inc. GST)
ATR75VA004-----Class 2 Transformer1 Threaded, 1 Side Opening- SGD 154.04
BTR75VA001-28-----Class 2 Transformer-- SGD 66.40
RFQ
CTR50VA027-----Class 2 TransformerFoot & Single Threaded Hubs- SGD 59.67
RFQ
DTR50VA022US----480/277/240/208/120 VACClass 2 Transformer-- SGD 108.78
BTR50VA005-28-----Class 2 Transformer-- SGD 55.23
RFQ
ETR40VA002US----120 VACClass 2 Transformer-- SGD 55.31
BTR150VA001-28-----Class 2 Transformer-- SGD 98.33
RFQ
FTR100VA027-----Class 2 TransformerFoot & Dual Threaded Hubs- SGD 77.05
RFQ
GTR100VA026-----Class 2 TransformerFoot & Dual Threaded Hubs- SGD 74.89
RFQ
HTR100VA015----480/277/240/208/120 VACClass 2 Transformer-- SGD 96.19
ITR100VA009US----480/277/240/208/120 VACClass 2 Transformer-- SGD 136.41
JTR100VA009----480/277/240/208/120 VACClass 2 Transformer-- SGD 84.01
KTR100VA002-20-----Class 2 TransformerFoot & Dual Threaded Hubs- SGD 72.69
RFQ
BTR100VA001-28-----Class 2 Transformer-- SGD 71.81
RFQ
LTR50VA0142.5"Not RatedIndoor3.06"277 VACClass 2 TransformerFoot or 1/2" NPT Hub24 VAC SGD 54.77
MTR50VA0052.5"Not RatedIndoor3"120 VACClass 2 TransformerFoot or 1/2" NPT Hub24 VAC SGD 52.93
NTR50VA0152.5"Not RatedIndoor3.06"120/208/240/277/480 VACClass 2 TransformerFoot or 1/2" NPT Hub24 VAC SGD 61.29
OTR75VA0012.5"Not RatedIndoor3"120 VACClass 2 TransformerFoot or 1/2" NPT Hub24 VAC SGD 69.43
PTR75VA0052.5"Not RatedIndoor3.03"120/208/240/480 VACClass 2 TransformerFoot or 1/2" NPT Hub24 VAC SGD 79.73
QTR100VA0012.5"Not RatedIndoor3.03"120 VACClass 2 TransformerFoot or 1/2" NPT Hub24 VAC SGD 79.92
RTR100VA0052.51"Not RatedIndoor3.03"120/240/277/480 VACClass 2 TransformerFoot or 1/2" NPT Hub24 VAC SGD 92.30
STR50VA0182.52"-Indoor3.48"208/240/277/480 VACControl TransformerFoot or 1/2" NPT Hub120 VAC SGD 67.10
TTR50VA0192.175"Not RatedIndoor2.896"120/277 VACClass 2 TransformerFoot24 VAC SGD 37.59
UTR50VA0012.178"Not RatedIndoor2.879"120 VACClass 2 TransformerFoot or 1/2" NPT Hub24 VAC SGD 37.41
VTR50VA0022.181"Not RatedIndoor2.908"120 VACClass 2 TransformerFoot or Dual 1/2" NPT Hub24 VAC SGD 47.90

Features

  • Functional Devices Class 2 transformers feature split-bobbin construction for superior isolation and low capacitive coupling.
  • They have foot and single / dual-threaded hubs for easy mounting.
  • These transformers operate at temperatures ranging from -30 to 140 degrees F.
  • Some Functional Devices RIB transformers are equipped with circuit breakers for overload protection.

Working Mechanism

  • Functional Devices Class 2 transformer operates on the fundamental principles of electromagnetic induction.
  • When alternating current (AC) flows through the primary winding of the transformer, it creates a magnetic field around it.
  • This magnetic field then induces a voltage in the secondary winding of the transformer, which is connected to the load or electronic device.
  • The transformer supplies a limited amount of power to the connected device.
  • This restriction prevents excessive voltage that could pose a risk of electrical shock.

Standards and Approvals

  • CE
  • RoHS
  • UL

Frequently Asked Questions

What distinguishes Class 2 transformers in terms of safety?

The distinctive feature of Class 2 transformers is their ability to provide a secure power source by ensuring that the output voltage remains within a predefined and safe range, thereby preventing electrical shock and safeguarding sensitive equipment.

How do Class 2 transformers contribute to operational efficiency?

Class 2 transformers contribute to operational efficiency by adapting to the specific power requirements of connected devices, minimising energy consumption and reducing wastage.

How do I choose the right Fundamental Devices RIB transformer for my specific application?

Choosing the right transformer involves considering factors, such as the power requirements of your devices, the voltage specifications of the transformer and any specific features needed for your application.