Condensate Pumps | Raptor Supplies Singapore

Condensate Pumps

Filter

Condensate pumps are used to return hot condensate to the feedwater holding tank in boiler rooms. They overcome gravity and pressure drops from long piping runs and back pressures in return lines.... Read More

LITTLE GIANT PUMPS -

VCMA-20 Series Condensate Removal Pump

StyleModelHPFlowVoltageHzCord LengthPrice (inc. GST)
A554461----- SGD 148.99
B554435----- SGD 180.32
LITTLE GIANT PUMPS -

Condensate Pump

StyleModelAmpsCord LengthDischargeFloat MaterialHeightHPItemLengthPrice (inc. GST)
A553507------Condensate Removal Pump--
RFQ
B550532------Condensate Removal Pump- SGD 240.53
C5544550.56ft.3/8" BarbPolypropylene7"1/30Condensate Pump10.5"-
RFQ
D5545310.66ft.3/8" BarbPolypropylene6.5"1/30Condensate Pump10 13/64"-
RFQ
C5544051.06ft.3/8" BarbPolypropylene7"1/50Condensate Pump10.5" SGD 176.01
E5531011.06ft.3/8" BarbPolypropylene9.75"1/50Condensate Pump12" SGD 388.24
F5505211.16ft.1/4" (M)NPTIntregal ABS Plastic4.437"1/150Condensate Pump7.437" SGD 373.39
G5532111.16ft.3/8" BarbPolypropylene10.5"1/18Condensate Pump12" SGD 281.44
C5544251.56ft.3/8" BarbPolypropylene7"1/30Condensate Pump10.5" SGD 171.02
H5545421.56ft.3/8" BarbPolypropylene6 51/64"1/30Condensate Pump10 5/16" SGD 157.14
I5545501.56ft.3/8" BarbPolypropylene6.5"1/30Condensate Pump10 13/64"-
RFQ
J5532012.56ft.3/8" BarbPolypropylene10.5"1/18Condensate Pump12" SGD 325.35
K5513203.59ft.1/2" (M)NPTABS Plastic6.5"1/12Condensate Pump12" SGD 769.22
StyleModelMax. Flow RateNoise LevelCooling CapacityPrice (inc. GST)
AHAR-83.17 Gal/Hr19 dBA30000 btu SGD 103.82
AHAR-155.28 Gal/Hr21 dBA45000 btu SGD 133.16
HARTELL -

HAT Series Reservoir Condensate Pumps

StyleModelVoltagePower ConsumptionMax. Flow RatePrice (inc. GST)
AHAT-1LP115V15W36 Gal/Hr SGD 92.53
BHAT-1DC115V60W56 Gal/Hr SGD 101.32
CHAT-1LT115V28W42.2 Gal/Hr SGD 89.91
AHAT-2LP230V15W36 Gal/Hr SGD 92.53
BHAT-2DC230V60W56 Gal/Hr SGD 101.32
AHAT-2LT230V28W42.2 Gal/Hr SGD 85.11
StyleModelHPInput CurrentVoltagePrice (inc. GST)
APABX-1151/201.6A115V SGD 544.44
APABX-2301/250.84A230V SGD 544.44
StyleModelVoltageTypeInput CurrentPrice (inc. GST)
AA2-115115VWithout Auxiliary Switch3.1A SGD 698.91
AA2-X115115VWith Auxiliary Switch3.1A SGD 717.44
AA2-230230VWithout Auxiliary Switch1.5A SGD 699.49
AA2-X230230VWith Auxiliary Switch1.5A SGD 718.03
StyleModelVoltageTypeInput CurrentInlet TypePrice (inc. GST)
AA2SA-115115VWithout Auxiliary Switch3.5AWithout Alternate Inlet SGD 836.67
AA2SA-X115115VWith Auxiliary Switch3.5AWithout Alternate Inlet SGD 831.10
AA2SA-115 W/ALT INLET115VWithout Auxiliary Switch3.5AWith Alternate Inlet SGD 853.50
AA2SA-X115 W/ALT INLET115VWith Auxiliary Switch3.5AWith Alternate Inlet SGD 846.18
AA2SA-230230VWithout Auxiliary Switch2AWithout Alternate Inlet SGD 839.49
AA2SA-X230230VWith Auxiliary Switch2AWithout Alternate Inlet SGD 832.17
AA2SA-230 W/ALT INLET230VWithout Auxiliary Switch2AWith Alternate Inlet SGD 854.57
AA2SA-X230 W/ALT INLET230VWith Auxiliary Switch2AWith Alternate Inlet SGD 847.25
StyleModelVoltageTypeInput CurrentPrice (inc. GST)
AAL2-115115VWithout Auxiliary Switch3.1A SGD 1072.32
AAL2-X115115VWith Auxiliary Switch3.1A SGD 1288.47
AAL2-230230VWithout Auxiliary Switch1.5A SGD 1098.98
AAL2-X230230VWith Auxiliary Switch1.5A SGD 1248.96
StyleModelVoltageTypePump RPMInlet TypePrice (inc. GST)
AL4-115/230115/230VWithout Auxiliary Switch3450Without Alternate Inlet SGD 1895.33
AL4X-115/230115/230VWith Auxiliary Switch3450Without Alternate Inlet SGD 1881.53
RFQ
AL4-115/230 W/ALT INLET115/230VWithout Auxiliary Switch3450With Alternate Inlet SGD 2051.70
AL4X-115/230 W/ALT INLET115/230VWith Auxiliary Switch3450With Alternate Inlet SGD 1911.52
LITTLE GIANT PUMPS -

VCMA-15 Series Condensate Removal Pump

StyleModelPrice (inc. GST)
A554401 SGD 72.13
B554415 SGD 143.98
B554411-
RFQ
StyleModelMax. Flow RateNoise LevelCooling CapacityPrice (inc. GST)
AHAD-83.17 Gal/Hr19 dBA30000 btu SGD 110.15
AHAD-155.28 Gal/Hr21 dBA45000 btu SGD 129.95
LITTLE GIANT PUMPS -

Condensate Removal Pump, Plenum Rated/Std, 1 Gal Tank, 1/3 Hp, 380/460VAC

ModelItemPrice (inc. GST)
553160104CR9QGQ SGD 1557.28
LITTLE GIANT PUMPS -

Condensate Removal Pump, Plenum Rated/Std, 1 Gal Tank, 1/8 Hp, 115VAC, 30 Ft

ModelItemPrice (inc. GST)
553130101CR9QGR SGD 1151.70
LITTLE GIANT PUMPS -

Condensate Removal Pump, Plenum Rated/Std, 1 Gal Tank, 1/8 Hp, 208-230VAC

ModelItemPrice (inc. GST)
553130102CR9QGT SGD 1169.45
LITTLE GIANT PUMPS -

Condensate Removal Pump, Plenum Rated/Std, 1 Gal Tank, 1/8 Hp, 277VAC, 30 Ft

ModelItemPrice (inc. GST)
553130104CR9QGU SGD 1253.05
SUPCO -

Condensate Removal Pump

ModelItemPrice (inc. GST)
SPCP115CU4VRP SGD 74.21
LITTLE GIANT PUMPS -

Plenum Use Condensate Pump, 1/30 HP, 115 V, 60 Hz

ModelItemPrice (inc. GST)
554221101CV8PLH SGD 195.02
LITTLE GIANT PUMPS -

Low Profile Condensate Pump, 115 V, 60 Hz

ModelItemPrice (inc. GST)
554201101CV8PLK SGD 143.70
LITTLE GIANT PUMPS -

Condensate Removal Pump, Plenum Rated/Std, 1 Gal Tank, 1/3 Hp, 115VAC, 60 Ft

ModelItemPrice (inc. GST)
553160101CR9QGN SGD 1476.58
LITTLE GIANT PUMPS -

Plenum Use Condensate Pump, 1/30 HP, 230 V, 50/60 Hz

ModelItemPrice (inc. GST)
554222101CV8PLJ-
RFQ
LITTLE GIANT PUMPS -

Low Profile Condensate Pump, 1/30 Hp, 230 V, 50/60 Hz

ModelItemPrice (inc. GST)
554202101CV8PLL-
RFQ
12

Condensate Pumps

Condensate pumps are used for collecting and removing condensate water from refrigeration, HVAC, steam and condensing boiler furnace systems. Raptor Supplies offers a wide range of condensate pumps from Little Giant, Dayton and Marvel. These pumps are electrically powered and run intermittently. Little Giant condensate pumps are used in high-efficiency gas furnaces, air conditioning units and condensing boilers where gravity drainage is not possible. These pumps have floats made of ABS plastic, polypropylene and polystyrene ensuring low friction, high tensile strength and excellent shock resistance. They can handle pressure up to 26 psi and can be operated at temperatures up to 140 degrees F. Marvel condensate pumps are designed for use with clear ice makers. They feature sealed reservoirs to prevent flooding & leaks, and provide a reservoir capacity of 38.9 oz. These UL and cUL listed pumps deliver an output of 1035 watts and can be operated at temperaturess up to 110 degrees F. These condensate pumps have current ratings ranging between 0.1 and 9 A.

Working Mechanism

  • Condensate pumps move water, known as condensate from the collection pan to a drain or discharge point.
  • When the water level in the collection pan rises, the pump activates and begins pumping water out.
  • Once the water level drops to a certain point, the pump turns off until needed again.

Features

Little Giant Condensate Removal Pumps :

  • These VCMA-20 Series pumps are powered by a 1/30 hp motor and have an ABS tank, motor cover & volute for durability and corrosion resistance.
  • They have a 1/2-gallon tank capacity to sufficiently handle condensation produced by boilers, furnaces and air conditioning systems.
  • These CSA-certified condensate removal pumps can withstand liquid temperatures up to 140 degrees F.

Hartell HAR Series Condensate Pumps :

  • They have a miniature design, requiring a smaller footprint for installations in limited spaces.
  • These condensate pumps utilise a 19 dBA diaphragm motor for ultra-quiet operation and vibration-free performance.
  • They are equipped with high-level alarms featuring volt-free contacts to open/close the pump when the tank detects excessive water levels.
  • These condensate pumps incorporate thermal overload protection to prevent motor failure due to dangerous overheating.

Frequently Asked Questions

What is the significance of high-level alarms in these condensate pumps?

High-level alarms are installed in a condensate tank that signals excessive build-up of condensate while protecting against leaks and overflows that may cause severe damage.

How do you install a condensate pump in a boiler?

  • Ensure the pump is free from packaging and debris, with clear venting slots.
  • Turn off the power at the fuse box.
  • Connect the power cord to the specified voltage from a constant power source.
  • Wire any safety switch according to the pump's specifications.
  • Securely mount the pump close to the air conditioning unit, below the coil drain, ensuring it is level.
  • Use screws to attach the pump to the wall, ensuring it won't splash or interfere with operation.
  • Use flexible tubing as the drain pipe, ensuring gravity assists in draining.
  • Consider installing a check valve on the discharge line to prevent backflow.
  • Turn the power back on and run the air conditioning unit to test the pump.
  • Ensure proper functioning of electrical components and check for leaks in the piping.

What is the recommended capacity for condensate pumps?

The typical Gallons Per Hour (GPH) capacity of condensate pumps ranges from 2 to 3 times the condensing rate of water per hour. For larger tanks, a capacity of 1.5 to 2 times the condensing rate may be sufficient.

How do I choose the right condensate removal pump for my applications?

Consider factors such as the amount of condensate produced, the size of the HVAC system, the installation space available and specific requirements or features you may have, such as alarm or automatic shutoff systems.

We are here to help!

Looking for a part not listed here?