DAYTON Direct Drive Single Inlet Forward Curve Blowers

Feature welded steel construction for structural rigidity and to resist oxidation on exposed surfaces. Grey epoxy coated housing for resistance from acids and harmful chemicals. Capable of withstanding ambient temperatures up to 104 degrees F

Filter
DAYTON -

Single Inlet Forward Curve Blowers

Dayton direct drive blowers are designed for industrial or commercial air moving applications. These units feature steel construction for corrosion resistance, durability and structural rigidity. They have single or three phase motors and forward-curved steel wheels to allow high-efficiency air volume with low rotational speeds, resulting in quieter operation. These units also feature direct drive mechanism that allows maximum efficiency (as there is less power loss due to fewer moving components) with optimal speeds. They come with OSHA complint fan guards to prevent accidental hazards and are available with capacitor start motors having blower speeds of 1140 and 1725 rpm.

StyleModelBlower RpmCfm @ 0.000-in. SpCfm @ 0.125-in. SpCfm @ 0.250-in. SpCfm @ 0.500-in. SpCfm @ 0.750-in. SpCfm @ 1.250-in. SpCfm @ 1.500-in. SpPrice (inc. GST)
A7AP8511401180116011251035855-- SGD 2121.28
A7AP7711401180116011251035855-- SGD 2120.74
A7AP871140206019701870171015001020- SGD 1849.33
A7AP741725595560515420300-- SGD 989.20
A7AP901725------1390 SGD 2246.98
A7AP891725------1848 SGD 2033.24
A7AP881725------1390 SGD 1746.68
B7AP861725151014501400129012001000- SGD 1881.04
A7AP831725985920870765655360- SGD 1493.11
A7AP8417251005968930850773480- SGD 1569.88
B7AP751725985920870765655360- SGD 1709.55
A7AP8117251005968930850773480- SGD 1589.78
A7AP801725985920870765655360- SGD 1448.79
A7AP791725595560515420300-- SGD 1189.23
B7AP781725151014501400129012001000- SGD 1839.53
A7AP7617251005968930850773480- SGD 1786.32
A7AP911725------1848 SGD 2426.06
DAYTON -

10-5/8 Inch Galvanized Steel Blowers

Dayton blowers offers a smooth flow of air / gas required for cooling, exhausting, aspirating, ventilating, conveying operations. These open dripproof blowers have a maximum inlet air and ambient temperature of 180 degrees F and 104 degrees F respectively. They feature welded steel construction with gray baked epoxy finish and housing that can be rotated to 8 discharge positions in each rotation. Choose from a range of these blowers, available in 16 and 19 inch widths.

StyleModelBearing TypeDepthFull Load AmpsMotor TypePhaseTypeVoltageWidthPrice (inc. GST)
A2C939-18"---Less Motor-19" SGD 1117.98
B7C454Ball17"2.8/1.4Three Phase3With Motor230/46016" SGD 1823.43
B7C453Sleeve17"11.3/5.5Capacitor Start1With Motor115/23016" SGD 1908.32
DAYTON -

Direct Drive Blowers, 9 Inch Wheel Diameter

Dayton blowers provide seamless flow of air / gas required for cooling, exhausting, aspirating, ventilating, conveying and more operations. They feature welded steel construction and housing that can be rotated to 8 discharge positions in each rotation. These blowers offer a maximum inlet air and ambient temperature of 180 degrees F and 104 degrees F, respectively. Choose from a range of these single inlet blowers from Dayton, available in motor less and with motor variants on Raptor Supplies

StyleModelTypeWheel BorePrice (inc. GST)
A2C938Less Motor5/8" SGD 1060.47
B7C039With Motor1/2" SGD 1271.78
DAYTON -

Motor Less Blower Ducts, 10-5/8 Inch

Dayton direct drive, single inlet, forward curve blowers are useful to circulate air in commercial and industrial applications. They feature single air inlets for pulling air from one side of the blower housing and direct-drive design for connecting the motor directly to the fan through shafts or axles, thereby increasing energy efficiency. These blowers have steel housing with grey polyester epoxy finish and forward curve, steel wheels, providing corrosion resistance & durability. Choose from a wide range of these blower ducts, available in variants with and without motor types.

StyleModelFull Load AmpsMotor TypePhaseTypeVoltagePrice (inc. GST)
A4C119---Less Motor- SGD 987.15
B7C5684.4/2.2Three Phase3With Motor230/460 SGD 2222.81
C7C40920.4/10.2Capacitor Start1With Motor115/230 SGD 1815.55
DAYTON -

Direct Drive Blower Ducts, 9 Inch

Dayton duct blowers are engineered to circulate air in industrial and commercial applications. They feature single air inlets for pulling air from one side of the blower housing. These duct blowers have belt drive design for flexibility in terms of rpm speeds, as the motor is not directly in contact with the fan's moving parts. These blowers have steel housing with grey baked polyester epoxy finish and forward curve, steel wheels, offering corrosion resistance and durability. Choose from a wide range of these belt drive, single inlet, forward curve blowers, available in variants with and without motor types.

StyleModelFull Load AmpsMotor TypePhaseTypeVoltagePrice (inc. GST)
A4C118---Less Motor- SGD 892.05
B7C5673.0/1.5Three Phase3With Motor230/460 SGD 2139.90
B7C40813.6/6.8Capacitor Start1With Motor115/230 SGD 2287.67
DAYTON -

Standard Forward Curved Blowers

StyleModelPrice (inc. GST)
A42NL22 SGD 131.72
B42NL21 SGD 154.09