Dayton hydronic unit heaters are designed for utilising non-potable hot water or steam produced by an indirect water heater or a boiler. These hydronic unit heaters are used in warehouses,... Read More

DAYTON -

Suspended Vertical Hydronic Wall & Ceiling Unit Heaters

Dayton suspended vertical hydronic heater units provide primary or supplementary heating by pushing and spreading the heated air. They are suspended from a wall or ceiling to spread the air evenly. These units store water, which is then heated by passing a current through rectangular coils and circulated with a maximum rate of 75 PSI. They feature a totally enclosed motor capable of producing a maximum power output of 3 HP. The heater units are ETL & ETLc listed and complies with OSHA standards for safe use. Choose from a wide range of unit heaters, available in single and three phase variants on Raptor Supplies.

StyleModelOutput @ 2 Psi SteamHeightDepthAir Flow RateMounting HeightPhaseOutput @ 200 Deg. F WaterMotor HpPrice (inc. GST)
A5PV6341300 btuH10 3/4"18 1/4"595 CFM11 ft.122700 btuH1/40 hp SGD 1888.13
A5PV6665500 btuH11 1/8"21 1/4"989 CFM12 ft.139600 btuH1/20 hp SGD 1960.94
A5PV6880600 btuH11 5/8"21 1/4"1200 CFM15 ft.148400 btuH1/20 hp SGD 2415.29
A5PV54101800 btuH12 1/8"25 1/4"1490 CFM14 ft.168300 btuH1/8 hp SGD 2505.11
A5PV55124400 btuH12 3/4"25 1/4"1790 CFM16 ft.183700 btuH167/1000 hp SGD 2791.54
A5PV56152000 btuH13 5/8"29 1/2"2220 CFM16 ft.1105200 btuH167/1000 hp SGD 3000.31
A5PV57173000 btuH14 1/8"29 1/2"2620 CFM18 ft.1118600 btuH167/1000 hp SGD 3136.84
A5PV59249800 btuH15 1/8"37 1/2"4180 CFM20 ft.1180100 btuH1/4 hp SGD 5410.87
A5PV60283800 btuH15 1/4"37 1/2"4430 CFM21 ft.1205400 btuH1/2 hp SGD 5644.67
A5PV61333400 btuH16 3/4"37 1/2"5210 CFM24 ft.3242900 btuH3/4 hp SGD 6154.26
A5PV62386000 btuH17 5/8"37 1/2"6140 CFM28 ft.3280800 btuH3/4 hp SGD 7092.79
A5PV64496000 btuH17 1/4"42"8020 CFM29 ft.3368100 btuH1 1/2 hp SGD 10046.29
A5PV65585000 btuH20 3/4"42"9450 CFM34 ft.3431100 btuH1 1/2 hp SGD 12380.87
A5PV67705000 btuH24 1/4"42"11000 CFM38 ft.3519400 btuH- SGD 13901.34
DAYTON -

Suspended Horizontal Hydronic Wall & Ceiling Unit Heaters

Dayton suspended horizontal hydronic heaters provide primary or supplementary heating by pushing and spreading the heated air. They are suspended from a wall or ceiling to spread the air evenly. These units store water which is then heated by passing a current through serpentine coils and circulated with a maximum rate of 150 PSI. They feature a totally enclosed motor which is capable of producing a maximum power output of 25W. They are ETL & ETLc listed and comply with OSHA standards for safe use. Choose from a wide range of these heaters, available in 245, 500, 580 and 850 CFM airflow ratings on Raptor Supplies.

StyleModelHeightDepthAir Flow RateMotor HpMounting HeightOutput @ 200 Deg. F WaterPowerAir Flow DirectionPrice (inc. GST)
A5PV1916"9 1/2"500 CFM16 W8 ft.18400 btuH16 WHorizontal SGD 1456.00
A5PV2216"9 1/2"580 CFM25 W9 ft.24800 btuH25 WHorizontal SGD 1604.59
A5YH1816"9 1/2"245 CFM16 W8 ft.8030 btuH16 WHorizontal SGD 1351.90
A5PV2618 1/2"10 1/2"850 CFM1/20 hp9 ft.35900 btuH-Horizontal SGD 1937.98
DAYTON -

Horizontal Hydronic Unit Heaters, Water Or Steam Heating

Dayton horizontal hydronic unit heaters mount on walls for heating large areas, commercial and industrial spaces. These heaters feature threaded female NPT connections for the supply of water or steam to heat the air and have fans to push & spread the heated air horizontally. They come with adjustable louvres for controlling the direction of airflow. Selected models allow vertical mountingon the ceiling to push the heated air downward towards the floor. Choose from a wide range of these heaters, available in airflow speeds ranging from 395 to 5500 cfm.

StyleModelAir Flow DirectionOutput @ 2 Psi SteamHeightDepthAir Flow RateMax. Operating PressureMax. Operating Temp.Motor Enclosure DesignPrice (inc. GST)
A1EBC1Horizontal240000 btuH30 1/4"14"3500 CFM150 psi366°FTotally Enclosed SGD 5567.76
A5PV32Horizontal180000 btuH29"14"2200 CFM75 psi320°FTotally Enclosed SGD 3975.47
A5YH19Horizontal120000 btuH25 1/4"14"1900 CFM75 psi320°FTotally Enclosed SGD 3031.06
A5PV53Horizontal96000 btuH24"14"1400 CFM75 psi320°FTotally Enclosed SGD 2877.98
A5PV52Horizontal96000 btuH24"14"1400 CFM75 psi320°FTotally Enclosed SGD 2705.16
A5PV51Horizontal84000 btuH24 1/4"12"1400 CFM75 psi320°FTotally Enclosed SGD 2470.43
A5PV50Horizontal72000 btuH21 3/4"11"1100 CFM75 psi320°FTotally Enclosed SGD 2361.19
A5PV49Horizontal72000 btuH21 3/4"11"1100 CFM75 psi320°FTotally Enclosed SGD 2188.37
A5PV48Horizontal60000 btuH20 1/2"11"900 CFM75 psi320°FTotally Enclosed SGD 2243.04
A5PV47Horizontal60000 btuH20 1/2"11"900 CFM75 psi320°FTotally Enclosed SGD 2100.49
A5PV46Horizontal48000 btuH20 1/4"11"750 CFM75 psi320°FTotally Enclosed SGD 1965.81
A5PV45Horizontal360000 btuH37 3/4"20"5500 CFM75 psi320°FTotally Enclosed SGD 7357.40
A5PV43Horizontal36000 btuH18"9"550 CFM75 psi320°FTotally Enclosed SGD 1689.46
A5PV35Horizontal204000 btuH29"14"2900 CFM75 psi320°FTotally Enclosed SGD 4522.67
A5PV34Horizontal204000 btuH29"14"2900 CFM75 psi320°FTotally Enclosed SGD 4411.45
A5PV33Horizontal180000 btuH29"14"2200 CFM75 psi320°FTotally Enclosed SGD 4210.10
A5PV31Horizontal18000 btuH15"9"395 CFM75 psi320°FTotally Enclosed SGD 1288.96
A1EBC2Horizontal280000 btuH30 1/4"18"4200 CFM150 psi366°FTotally Enclosed SGD 6176.55
A5PV30Horizontal156000 btuH27 3/4"14"2600 CFM75 psi320°FTotally Enclosed SGD 3963.37
A1EBC3Horizontal300000 btuH37 3/4"19"5000 CFM150 psi366°FTotally Enclosed SGD 7077.87
A1EBC4Horizontal360000 btuH37 3/4"20"5500 CFM150 psi366°FTotally Enclosed SGD 7643.76
A3DUF7Horizontal24000 btuH18"9"450 CFM150 psi355°FTotally Enclosed SGD 1608.06
A4NHG4Horizontal240000 btuH30 1/4"14"3500 CFM150 psi366°FTotally Enclosed SGD 5281.40
A4NHG5Horizontal280000 btuH30 1/4"18"4200 CFM150 psi366°FTotally Enclosed SGD 5806.11
A4NHG6Horizontal300000 btuH37 3/4"19"5000 CFM150 psi366°FTotally Enclosed SGD 6672.31

Hydronic Unit Heaters

Hydronic unit heaters utilize non-potable hot water or steam produced by a boiler, indirect water heater. Dayton heaters save floor space and are therefore commonly used in large areas like manufacturing facilities, warehouses and garages. These heaters are capable of pushing heated air horizontally and vertically and spread it across a larger area. Choose from a broad range of these Dayton hydronic heating units, available in 11000 cfm, 500 cfm, 450 cfm, 395 cfm and 245 cfm air flow options.

Working Mechanism

  • Hot water is produced by a central boiler for heating the water to the required temperature.
  • The hot water is then circulated through a series of heating coils / radiators within the unit heater.
  • The heat from the hot water is then transferred to the surrounding air through the heating coils.
  • A fan or blower inside the unit heater circulates the warm air into the heated space.
  • The cooled water then returns to the central boiler for reheating and the cycle repeats.
  • The temperature of the hot water is then controlled by adjusting the temperature setting on the central boiler and the amount of heat produced by the unit heater can be adjusted by controlling the flow of hot water through the heating coils or radiators.

Features

  • Dayton water & steam heated horizontal hydronic unit heaters come with fans to spread & push the heated air horizontally. These heaters have threaded female NPT connections to supply water / steam for heating the air and are equipped with adjustable louvres to control the direction of airflow. They can be mounted on walls for heating industrial spaces.
  • Dayton suspended vertical hydronic heaters are mounted on the ceiling or wall vertically to spread the air evenly. They feature a totally enclosed motor for protection from dust and have a maximum operating pressure of 75 PSI. These heater units are ETL & ETLc listed and comply with OSHA standards for safe & secure operations.
  • Dayton water heated horizontal hydronic unit heaters are suspended from a wall / ceiling horizontally to spread the air evenly. These units heat the stored water by passing a current through serpentine coils.

Frequently Asked Questions

What is the flow rate of Dayton hydronic unit heaters?

The flow rate of these heaters range from 245 to 11000 cfm.

What safety precautions should be taken when using hydronic unit heaters?

  • Get the system installed by a qualified technician.
  • Inspect the central boiler regularly and maintain it to ensure safe operation.

What is the role of a thermostat in hydronic unit heaters?

The thermostat controls the temperature of the hot water and the rate of heat transfer. The thermostat is set to the desired temperature and will turn the unit on and off as needed to maintain the required temperature.

We are here to help!

Looking for a part not listed here?