DWYER INSTRUMENTS 2000 Series Magnehelic Differential Pressure Gages | Raptor Supplies Singapore

DWYER INSTRUMENTS 2000 Series Magnehelic Differential Pressure Gages

Dwyer Magnehelic gauges are used in isolation / medical environments. They employ simple, frictionless gauge movement to quickly indicate air or non-corrosive gas pressures that can be either ...Read More

Filter
StyleModelAccuracyItemPressure RangePrice (inc. GST)
A
2000-100CM
-Gauge- SGD 163.56
B
2000-80CM
-Gauge- SGD 163.56
B
2000-30CM
-Gauge- SGD 166.83
B
2001-ASF
-Gauge- SGD 190.55
A
2003-ASF
-Gauge- SGD 192.18
A
2001-LT
-Gauge- SGD 193.17
A
2002-ASF
-Gauge- SGD 189.60
A
2202
-Gauge- SGD 170.93
C
2010-LT
-Gage- SGD 197.47
A
2003-LT
-Gage- SGD 197.47
A
2300-10CM
-Gauge- SGD 197.34
A
2000-200CM
-Gauge- SGD 176.64
B
2000-125PA
-Gauge- SGD 151.32
B
2000-1.5KPA
-Gauge- SGD 155.83
D
2020
-/+ 2%Differential Pressure Gauge0 to 20" wc SGD 184.66
E
2040
-/+ 2%Differential Pressure Gauge0 to 40" wc SGD 202.14
F
2030
-/+ 2%Differential Pressure Gauge0 to 30" wc SGD 154.94
G
2000-0
-/+ 2%Differential Pressure Gauge0 to 0.5" wc SGD 179.29
H
2008
-/+ 2%Differential Pressure Gauge0 to 8" wc SGD 181.96
I
2004
-/+ 2%Differential Pressure Gauge0 to 4" wc SGD 182.50
J
2010-AV
-/+ 2%Differential Pressure Gauge0 to 10" wc SGD 204.12
K
2001
-/+ 2%Differential Pressure Gauge0 to 1" wc SGD 159.63
L
2002
-/+ 2%Differential Pressure Gauge0 to 2" wc SGD 193.03
M
2005
-/+ 2%Differential Pressure Gauge0 to 5" wc SGD 190.15
N
2010
-/+ 2%Differential Pressure Gauge0 to 10" wc SGD 125.93
O
2025
-/+ 2%Differential Pressure Gauge0 to 25" wc SGD 164.25
P
2100
-/+ 2%Differential Pressure Gauge0 to 100" wc SGD 162.99
Q
2060
-/+ 2%Differential Pressure Gauge0 to 60" wc SGD 172.59
R
2210
-/+ 2%Differential Pressure Gauge0 to 10 psi SGD 396.68
S
2302
-/+ 2%Differential Pressure Gauge1 to 0 to 1" wc SGD 179.95
T
2310
-/+ 2%Differential Pressure Gauge5 to 0 to 5" wc SGD 170.22
U
2215
-/+ 2%Differential Pressure Gauge0 to 15 psi SGD 452.78
V
2205
-/+ 2%Differential Pressure Gauge0 to 5 psi SGD 200.03
W
2050
-/+ 2%Differential Pressure Gauge0 to 50" wc SGD 200.83
X
2330
-/+ 2%Differential Pressure Gauge15 to 0 to 15" wc SGD 195.34
Y
2000-0AV
-/+ 2%Differential Pressure Gauge0 to 0.5" wc SGD 284.50
Z
2002-AV
-/+ 2%Differential Pressure Gauge0 to 2" wc SGD 218.35
A1
2230
-/+ 2%Differential Pressure Gauge0 to 30 psi SGD 702.55
B1
2001-AV
-/+ 2%Differential Pressure Gauge0 to 1" wc SGD 208.50
C1
2003
-/+ 2%Differential Pressure Gauge0 to 3" wc SGD 180.63
D1
2006
-/+ 2%Differential Pressure Gauge0 to 6" wc SGD 192.07
E1
2015
-/+ 2%Differential Pressure Gauge0 to 15" wc SGD 195.70
F1
2300-0
-/+ 2%Differential Pressure Gauge0.25 to 0 to 0.25" wc SGD 157.60
G1
2000-00AV
-/+ 4%Differential Pressure Gauge0 to 0.25" wc SGD 276.80
H1
2000-00
-/+ 4%Differential Pressure Gauge0 to 0.25" wc SGD 167.65
I1
2300-60PA
-/+ 4%Differential Pressure Gauge-30 to 30 Pa SGD 170.22

Features

  • Break-resistant, clear plastic face for undistorted viewing, even from afar.
  • Precision litho-printed scale for accuracy and easy reading.
  • Patented design for quick response to pressure changes, meaning no delay in assessing critical situations.
  • Bezel to enable flush mounting in the panel.
  • Easy to see red-tipped pointer of heat-treated aluminium tubing, rigidly mounted on the helix shaft.
  • Pointer stops of molded rubber to prevent pointer over-travel without damage.
  • Conveniently located zero adjustment screw in the plastic cover accessible without removing the cover.
  • O-ring seal to provide pressure tightness.

Compatible Accessories

  • Dwyer Instruments A-605 Air Filter Kits: Adapt any standard Magnehelic gauge for use as an air filter gauge.
  • Dwyer Instruments A-432 Gauge Portable Kits: Plastic carrying case for Magnehelic gauges of standard range. Include 9 ft (2.7m) of rubber tubing (3/16 inch I.D.), stand-hang bracket & terminal tube with holder.

Standards and Approvals

  • CE
  • RoHS

Frequently Asked Questions

How will the installation of a Magnehelic gauge 150 ft away from the pressure source affect accuracy?

While accuracy will be unaffected, response time will increase proportionally to the length of the tubing.

We are here to help!

Looking for a part not listed here?