EATON C Series Complete Molded Case Circuit Breakers, J Frame | Raptor Supplies Singapore

EATON C Series Complete Molded Case Circuit Breakers, J Frame

Eaton J-frame complete moulded case circuit breakers are electrical safety devices designed to protect electrical systems from damage due to current overloading or short circuits.

Filter
StyleModelPrice (inc. GST)
A
JG3175A12S41
--
RFQ
A
JG3250S46
- SGD 10,054.42
A
JG3225M01S42
- SGD 7,255.07
A
JG3250B05S41
- SGD 10,912.12
A
JG3225S41
- SGD 7,237.85
A
JG3250S45
- SGD 9,737.35
A
JG3250S48
- SGD 10,054.42
A
JG3250A12S41
- SGD 11,769.86
A
JG3250C04S41
- SGD 11,769.86
A
JG3250S41
- SGD 10,054.42
A
JG3225S42
- SGD 7,237.85
A
JG3250XD14
- SGD 7,284.57
A
JG3250XA12D14S43
- SGD 11,912.37
A
JG3250WS42
- SGD 9,737.35
B
SPECIAL603
--
RFQ
B
SPECIAL604
- SGD 15,152.85
B
SPECIAL606
- SGD 17,626.52
B
SPECIAL609
--
RFQ
B
SPECIAL605
- SGD 17,626.52
A
JG3225S46
- SGD 7,506.53
A
JG3200S45
- SGD 7,237.85
A
JG3175S41
- SGD 7,237.85
A
JG3200M01
--
RFQ
A
JG3175C04S41
--
RFQ
A
JG3175S46
- SGD 7,506.53
A
JG3175B05S41
- SGD 8,098.08
A
JG3175A05S41
--
RFQ
A
JG3175M01
--
RFQ
A
JG3175S45
- SGD 7,237.85
A
JG3200A05S41
- SGD 8,098.08
A
JG3200A12S41
- SGD 8,990.20
A
JG3200B05S41
- SGD 8,098.08
A
JG3225A05S41
--
RFQ
A
JG3175S42
- SGD 7,237.85
A
JG3200C04S41
--
RFQ
A
JG3225C04S41
--
RFQ
A
JG3250A05S41
- SGD 10,912.12
A
JG3225A12S41
--
RFQ
A
JG3225B05S41
- SGD 8,098.08
A
JG3225M01
--
RFQ
A
JG3200S41
--
RFQ
B
SPECIAL607
--
RFQ

Working Mechanism

  • When the current flowing through the circuit exceeds the rated level, these circuit breakers interrupt the flow of electricity to the circuit, protecting the equipment from detecting a fault.
  • They can be reset by switching the handle to Off & On positions once the fault is resolved.

Features

  • They have a moulded case construction, which provides durability and protection against mechanical damage.
  • These J-frame complete MCCBs have a sliding handle with ON & OFF positions for easy identification of the breaker's status.
  • They are equipped with a 3-pole configuration for controlling multiple connections simultaneously.
  • These MCCBs are available in current ratings ranging from 63 to 250A.
  • Selected models have a built-in test kit for electronic field testing and a push-to-trip button to check the tripping function during scheduled maintenance.

Standards and Approvals

  • UL
  • CSA
  • CE
  • KEMA
  • KEUR
  • IEC

Frequently Asked Questions

What is the difference between MCCBs and MCBs?

  • MCBs protect items from current overloads while MCCBs protect equipment from fault currents & excess temperature rise.
  • The tripping circuit of MCBs is fixed while MCCBs have a movable tripping circuit.
  • MCBs have comparatively low interrupting ratings than MCCBs.

How to install a circuit breaker?

  • Remove the panel cover. Use a screwdriver to unscrew all four edges of the panel cover while holding it tight to prevent it from slipping off.
  • Connect the neutral and ground wires.
  • Place the breaker inside.
  • Screw the panel cover back.

What are the reasons for frequent tripping of the circuit breaker?

A circuit overload, short-circuiting, ground fault surges, defective circuit breaker or an arc fault can cause tripping of the circuit breaker.

We are here to help!

Looking for a part not listed here?