EATON CH Series Ground Fault Circuit Breakers | Raptor Supplies Singapore

EATON CH Series Ground Fault Circuit Breakers

Eaton CH-Series ground fault circuit breakers are designed to protect electrical systems and equipment from damage caused by ground faults. They can detect and interrupt fault currents as low as 5mA.

Filter
StyleModelAmpsNumber Of PolesVoltagePrice (inc. GST)
A
CH215GFTCS
--- SGD 1,409.94
A
CH220GFTX36
--- SGD 1,260.60
B
CHFGFT130
----
RFQ
B
CHFGFT115
--- SGD 237.76
C
CHFGF115CS
--- SGD 346.24
C
CHFGF115
--- SGD 185.24
D
CHFGFT120PN
--- SGD 185.24
B
CHFGFT120
----
RFQ
A
CH220GFT
--- SGD 429.00
E
CHFGFT115PN
--- SGD 185.24
A
CH225GFTT3
----
RFQ
A
CH225GFTCS
----
RFQ
A
CH225GFT
--- SGD 473.59
A
CH230GFTX36
--- SGD 1,260.64
A
CH230GFTCS
--- SGD 1,557.95
A
CH230GFT
--- SGD 461.56
A
CH230GFTT3
--- SGD 1,329.08
A
CH215GFTT3
----
RFQ
C
CHFGF120
----
RFQ
A
CH260GFTCS
--- SGD 1,409.94
A
CH260GFT
--- SGD 562.81
A
CH215GFT
--- SGD 429.00
A
CH220GFTT3
--- SGD 1,577.88
A
CH220GFTCS
--- SGD 1,351.83
A
CH235GFT
--- SGD 517.23
A
CH240GFTCS
--- SGD 1,409.94
A
CH235GFTT3
--- SGD 1,329.08
A
CH240GFTX36
--- SGD 1,260.60
A
CH240GFT
--- SGD 429.00
A
CH240GFTT3
--- SGD 1,577.88
A
CH235GFTCS
--- SGD 1,447.29
F
CH245GFTX36
--- SGD 1,602.31
F
CH245GFT
--- SGD 464.81
F
CH245GFTCS
----
RFQ
A
CH250GFT
--- SGD 473.59
A
CH250GFTCS
----
RFQ
A
CH250GFTX36
--- SGD 1,260.60
A
CH260GFTX36
--- SGD 1,349.82
C
CHFGF115PN
151120/240V SGD 185.24
G
CHN220GF
202120/240V SGD 379.72
C
CHFGF120PN
201120V SGD 233.31
G
CH240GF
402120/240V SGD 505.72
G
CH250GF
502120/240V SGD 661.36

Working Mechanism

  • Ground fault circuit breakers monitor the current flowing through the hot and neutral conductors.
  • If there is an imbalance in the current, they indicate a ground fault and the breaker trips, interrupting power to the circuit.

Features

  • They can accommodate wire sizes ranging from 14 to 4 AWG.
  • These CH-Series ground fault circuit breakers feature plug-on connection for easy installation.
  • They are available in amperage ratings ranging from 15 to 50A.
  • Selected models feature a mechanical trip flag for visual indication of the tripped status and have a 1-step reset functionality.

Frequently Asked Questions

What is the difference between a GFCI breaker and a regular breaker?

Regular breakers only protect from short circuits and overcurrents, while GFCI breakers provide additional protection from ground faults.