EATON DK Series Complete Molded Case Circuit Breakers, K Frame | Raptor Supplies Singapore

EATON DK Series Complete Molded Case Circuit Breakers, K Frame

Eaton DK Series complete MCCBs are used in motor control centres, switchboards, panelboards and busways to protect electrical systems from overcurrent and short circuit conditions.

Filter
StyleModelAmpsNumber Of PolesPrice (inc. GST)
A
DK3400X
---
RFQ
A
DK3350X
-- SGD 10,547.57
A
DK3250V
-- SGD 11,342.74
A
DK3300S42
-- SGD 13,933.74
A
DK3300S10
-- SGD 13,933.74
A
DK3300W
-- SGD 4,264.39
A
DK3300Y
-- SGD 11,161.68
A
DK3300Z15
-- SGD 11,342.74
A
DK3350WS42
---
RFQ
A
DK3350VW
-- SGD 10,814.27
A
DK3350W
---
RFQ
A
DK3300X
-- SGD 10,547.57
A
DK3300Z01
-- SGD 11,342.74
A
DK3400A02
---
RFQ
A
DK3400H08
-- SGD 12,490.25
A
DK3300WS10
-- SGD 13,383.24
A
DK3350Y
-- SGD 11,161.68
A
DK3400U22
-- SGD 13,933.74
A
DK3400WS10
-- SGD 13,383.24
A
DK3400V
-- SGD 4,462.24
A
DK3400S10
-- SGD 13,945.98
A
DK3400WJ01
-- SGD 12,930.62
A
DK3400WS32
---
RFQ
A
DK3400W
-- SGD 3,774.93
A
DK3400S09
---
RFQ
A
DK3400XS10
-- SGD 13,676.84
A
DK3400Y
---
RFQ
A
DK3400WS42
-- SGD 12,759.35
A
DK3300V
-- SGD 10,801.98
A
DK3300H08
---
RFQ
B
DK2350W
-- SGD 9,047.77
A
DK3250C
-- SGD 11,396.58
B
DK2300V
-- SGD 9,439.21
B
DK2350V
---
RFQ
B
DK2250W
-- SGD 9,047.77
B
DK2300X
---
RFQ
B
DK2300W
-- SGD 9,770.90
B
DK2300S47
---
RFQ
B
DK2350
---
RFQ
B
DK2400H08
-- SGD 9,006.16
B
DK2400D11
-- SGD 9,157.86
B
DK2400KA06X07Y03
-- SGD 9,243.48
B
DK2400C
---
RFQ
B
DK2300
-- SGD 4,264.39
B
DK2400KA06X07Y08
---
RFQ
B
DK2400KA05X07Y08
-- SGD 10,241.73
B
DK2400W
-- SGD 9,770.90
A
DK3250W
-- SGD 4,264.39
A
DK3250H08
-- SGD 10,819.17
B
DK2400Y
-- SGD 9,265.52
A
DK3250WS42
-- SGD 13,627.92
A
DK3300B06
---
RFQ
A
DK3250S42
-- SGD 14,398.64
A
DK3300C
-- SGD 11,362.31
A
DK3250Y
-- SGD 11,161.68
B
DK2250
-- SGD 9,057.56
A
DK3250
250A3 SGD 4,264.39
C
DK3350
350A3 SGD 4,264.39
B
DK2400
400A2 SGD 4,264.39

Features

  • These MCCBs have 2 / 3 pole configurations for controlling multiple connections simultaneously.
  • They are equipped with a sliding switch with an On / Off function to identify the functioning of the circuit breaker.
  • These K-frame circuit breakers have a moulded case construction, which provides increased durability and protection against mechanical damage.
  • They are available in amperage ratings of 250, 350 and 400A.

Frequently Asked Questions

What are the reasons for frequent tripping of the circuit breaker?

Current overloads, short-circuits, ground fault surges, defective circuit breakers or an arc fault can cause tripping of the circuit breaker.

What are the points to inspect before operating the circuit breaker?

  • Keep the area around the breaker clean by using an enclosure. Remove the dust, dirt, grease, moisture, foreign contaminants or any safety hazards near the circuit breaker area.
  • Check that the unit's mechanical linkages, like the toggle actuator, are free to move by switching the unit On & Off several times.
  • Press the optional push-to-trip button at the bottom side of the unit to mechanically test the circuit breaker.
  • Inspect the unit for any cracks, chipping, discolouration or any sign of overheating. Tighten the terminals & connectors. Check the mounting hardware.

We are here to help!

Looking for a part not listed here?