EATON FD Series Complete Molded Case Circuit Breakers, F Frame

Eaton Series C molded case circuit breakers reduce risks of damage by fault currents and fatal electrical shocks.

Filter
StyleModelAmpsNumber Of PolesVoltagePrice (inc. GST)
A
FD3225BP10
----
RFQ
B
FD3080VL
----
RFQ
B
FD3100LM08
--- SGD 2,244.76
B
FD3100LJ01
--- SGD 2,684.89
B
FD3100LM04
--- SGD 2,181.54
B
FD3100L
--- SGD 2,742.20
B
FD3100H08
--- SGD 2,543.45
B
FD3100KWA06D15L08U14
--- SGD 3,858.79
B
FD3100H01
--- SGD 2,811.39
B
FD3100KLA12S03
--- SGD 3,695.14
B
FD3100BP10
--- SGD 4,947.35
B
FD3090J01F01H08
----
RFQ
B
FD3100H10
--- SGD 2,458.28
B
FD3090VL
--- SGD 2,244.76
B
FD3100V
--- SGD 2,311.47
B
FD3090VW
----
RFQ
B
FD3090V
--- SGD 2,234.02
B
FD3080VH09
--- SGD 2,458.28
B
FD3090L
----
RFQ
B
FD3080VW
--- SGD 2,224.49
B
FD3080V
----
RFQ
B
FD3090BP10
--- SGD 2,222.56
B
FD3080LS22
--- SGD 7,009.69
B
FD3080LM08
----
RFQ
B
FD3080LS06
----
RFQ
B
FD3080LM04
--- SGD 2,271.00
B
FD3070VW
--- SGD 2,324.60
B
FD3100LF06
--- SGD 2,468.98
B
FD3100LU13
--- SGD 6,528.61
B
FD3080BP10
--- SGD 2,222.56
B
FD3125A02S22
--- SGD 6,512.43
B
FD3125LM08S24
--- SGD 6,291.75
B
FD3125LA02U82
--- SGD 6,739.04
B
FD3125L
--- SGD 6,281.85
B
FD3125J01
--- SGD 6,035.31
B
FD3125LA02U62
--- SGD 6,756.92
B
FD3125LA02
----
RFQ
B
FD3125LA14
--- SGD 6,089.00
B
FD3125A10
--- SGD 5,877.86
B
FD3125H01
--- SGD 6,011.46
B
FD3125BP10
----
RFQ
B
FD3110V
--- SGD 5,027.42
B
FD3100VSH09
----
RFQ
B
FD3100LD12M04
--- SGD 2,271.00
B
FD3125A02
--- SGD 5,635.73
B
FD3110L
--- SGD 5,352.65
B
FD3110LW02
----
RFQ
B
FD3100W02
--- SGD 2,940.48
B
FD3110VH09
--- SGD 5,712.55
B
FD3110J01
----
RFQ
B
FD3100VWH09
----
RFQ
B
FD3110BP10
--- SGD 5,001.61
B
FD3100VH09
--- SGD 2,568.89
B
FD3100VL
----
RFQ
B
FD3100VW
--- SGD 2,224.49
B
FD3100VLM04
--- SGD 2,181.54
B
FD3080H01
--- SGD 2,675.34
B
FD3080L
--- SGD 2,618.96
B
FD3125LS01
--- SGD 6,285.78
B
FD3040VW
--- SGD 1,957.31
B
FD3015Z01
--- SGD 1,989.53
12...78

Working Mechanism

  • Eaton molded case circuit breakers are equipped with fixed thermal and fixed magnetic trips.
  • The thermal trip comprises a bi-metallic strip that gets heated when an overcurrent passes through the conductors, causing the contacts to open and interrupt the current flow.
  • The magnetic trip, on the other hand, has an electromagnetic component that detects the presence of a short circuit.
  • As the current rises abruptly, a magnetic field is created that causes the displacement in the tripping coil.
  • This opens the contact again and stops the current flow, preventing any further damage to the equipment.

Features

  • These circuit breakers feature a non-interchangeable, thermal-magnetic trip that avoids nuisance tripping on mild overloads while reacting instantly when exposed to faulty currents, thus providing maximum protection.
  • They feature a contact design that offers high-speed blow-open action, resulting in superior performance and eliminating the risk of potential hazards.
  • These FD Series complete MCCBs come with an enhanced, easy-to-use interface, allowing the operator to view and make adjustments to the trip settings.
  • They are integrated with load-side terminals for easy installation with panelboards and load centres.

Standards and Approvals

  • UL

Frequently Asked Questions

How to maintain the frame of these molded case circuit breakers?

  • Inspect the frame regularly for any signs of damage or wear like cracks, chips or corrosion.
  • Use a soft brush or cloth to remove any dirt, dust or debris from the frame.
  • Always lubricate moving parts of the frame including hinges or latches to ensure smooth operation.

What is the function of molded cases?

Molded cases hold current-carrying components, trip devices and mechanisms integrated into one unit.

We are here to help!

Looking for a part not listed here?