EATON GD Series Complete Molded Case Circuit Breakers, G Frame | Raptor Supplies Singapore

EATON GD Series Complete Molded Case Circuit Breakers, G Frame

Eaton GD Series moulded case circuit breakers reduce risks of damage by fault currents and fatal electrical shocks.

Filter
StyleModelAic RatingAmpsNumber Of PolesPrice (inc. GST)
A
GD3100DA3
--- SGD 4,154.44
B
GD3015B3
--- SGD 3,464.49
C
GD2050A3
--- SGD 2,588.58
C
GD2040C
----
RFQ
C
GD2035
----
RFQ
C
GD2040DA3
--- SGD 2,588.58
C
GD2045A3
--- SGD 2,678.28
C
GD2045
--- SGD 649.74
C
GD2050DV
----
RFQ
C
GD2050DA3
--- SGD 2,588.58
C
GD2045D
----
RFQ
B
GD3015A6
--- SGD 3,572.11
B
GD3015A3
----
RFQ
C
GD2050D
--- SGD 1,390.22
B
GD3015DB3
--- SGD 3,373.93
B
GD3015DA3S114
--- SGD 5,935.62
B
GD3015DA3
--- SGD 3,532.97
B
GD3015CA3
--- SGD 3,532.97
B
GD3015A3S7
----
RFQ
C
GD2040A3
--- SGD 2,678.28
B
GD3015DV
--- SGD 2,270.51
D
GD3080S3
----
RFQ
C
GD2020DA3
--- SGD 2,588.58
C
GD2025DV
--- SGD 1,289.38
C
GD2025DA3
--- SGD 2,588.58
D
GD3080D
----
RFQ
C
GD2025A3
----
RFQ
E
GD3035
--- SGD 905.76
C
GD2025
--- SGD 1,390.22
C
GD2030C
----
RFQ
C
GD2040D
----
RFQ
C
GD2030D
--- SGD 1,317.78
C
GD2035A3
--- SGD 2,588.58
C
GD2035DA3
----
RFQ
C
GD2035C
--- SGD 1,289.38
C
GD2035D
----
RFQ
C
GD2045C
--- SGD 1,289.38
C
GD2050C
----
RFQ
B
GD3015D
--- SGD 2,451.16
B
GD3015S114
--- SGD 6,043.24
C
GD2020D
--- SGD 1,289.38
F
GD3030DVB3
--- SGD 3,263.84
G
GD3060DS3
--- SGD 4,939.83
H
GD3025S2
----
RFQ
G
GD3060D
--- SGD 2,270.51
H
GD3025D
--- SGD 2,495.96
G
GD3060DA3
--- SGD 3,532.97
F
GD3030DV
--- SGD 2,443.17
G
GD3060S1
--- SGD 4,837.05
I
GD3070C
----
RFQ
J
GD3050DS101
----
RFQ
F
GD3030DA3
----
RFQ
I
GD3070S1
----
RFQ
F
GD3030VFF01
----
RFQ
I
GD3070DA3
----
RFQ
F
GD3030V
--- SGD 2,723.16
I
GD3070D
--- SGD 2,892.01
E
GD3035A3
--- SGD 3,695.90
H
GD3025S1
----
RFQ
F
GD3030CA3
----
RFQ
K
GD3020DA3S114
--- SGD 5,935.62

Working Mechanism

  • Eaton GD Series moulded case circuit breakers feature fixed thermal and fixed magnetic trips to protect against faulty currents:

Fixed Thermal Trips

  • The thermal trip consists of a bimetallic strip which gets heated and bends when an overcurrent passes through the conductors, which opens the contacts and interrupts the current flow.

Fixed Magnetic Trips

  • The magnetic trip has an electromagnetic component that detects the presence of short circuits in a circuit.
  • As the current rises, a magnetic field is generated that trips the breaker and causes the contacts to open and stop the current flow.

Features

  • These units feature a fixed thermal and fixed magnetic trip unit to avoid nuisance tripping in mild current fluctuation but are highly sensitive to heavy inrush current, thus producing both instantaneous and time-delayed current limiting protection.
  • They have a compact, space-saving design that provides installation in tight spaces and allows for high-speed blow-open action, resulting in superior performance.
  • They are integrated with line and load side terminals for easy installation with panelboards and load centres.
  • These MCCBs also include a toggle and a mechanical latching mechanism that ensures the circuit breaker remains in the tripped position until it is manually reset.

Standards and Approvals

  • UL

Frequently Asked Questions

What is the advantage of moulded cases?

Moulded cases hold current-carrying components, trip devices and mechanisms integrated into one unit.

What is the purpose of a G-frame?

A G-frame is a modular design that provides a versatile and flexible platform to accommodate low-voltage circuit breakers. They also protect electrical systems from damage caused by overloads and short circuits, as well as mechanical stress.

What is the purpose of a toggle?

These circuit breakers come with an integrated over-centre toggle for visual indication of tripped status.

We are here to help!

Looking for a part not listed here?