EATON GD Series Complete Molded Case Circuit Breakers, G Frame

Eaton GD Series moulded case circuit breakers reduce risks of damage by fault currents and fatal electrical shocks.

Filter
StyleModelAic RatingAmpsNumber Of PolesPrice (inc. GST)
A
GD3045D
--- SGD 2,270.51
B
GD3070S3
--- SGD 4,014.99
C
GD3060A3S7
--- SGD 5,952.75
C
GD3060DA3
--- SGD 3,532.97
C
GD3060G1
----
RFQ
C
GD3060S1
--- SGD 4,837.05
B
GD3070A3
----
RFQ
B
GD3070C
----
RFQ
B
GD3070A3S7
--- SGD 6,574.21
B
GD3070S1
----
RFQ
B
GD3070DA3
----
RFQ
C
GD3060D1S3
--- SGD 4,939.83
B
GD3070G2
--- SGD 2,945.77
B
GD3070D
--- SGD 2,892.01
D
GD3080C
--- SGD 2,925.86
D
GD3080DA3
--- SGD 4,154.44
E
GD3030CA3
----
RFQ
D
GD3080S3
----
RFQ
F
GD3025CA3
--- SGD 3,464.49
G
GD3090DS3
--- SGD 5,597.99
C
GD3060D
--- SGD 2,270.51
C
GD3060DS3
--- SGD 4,939.83
D
GD3080D
----
RFQ
H
GD3020DS1
--- SGD 4,939.83
H
GD3020CA3
--- SGD 3,655.44
H
GD3020A3
--- SGD 3,584.54
I
GD3015DS1
--- SGD 4,939.83
RFQ
J
GD3015DVA6
--- SGD 4,426.01
H
GD3020DA3
----
RFQ
H
GD3020A3S7
----
RFQ
H
GD3020DB3
----
RFQ
H
GD3020
--- SGD 830.88
H
GD3020DV
--- SGD 2,270.51
C
GD3060G2
--- SGD 2,309.64
H
GD3020D
--- SGD 2,451.16
H
GD3020S1
--- SGD 5,004.69
F
GD3025A3
----
RFQ
K
GD3050C
--- SGD 2,451.16
C
GD3060C
--- SGD 2,216.70
K
GD3050D
--- SGD 2,349.21
C
GD3060A3
--- SGD 3,655.44
K
GD3050DS101
----
RFQ
F
GD3025S1
----
RFQ
E
GD3030A3
----
RFQ
H
GD3020C
--- SGD 2,451.16
L
GD3040A3
--- SGD 3,584.54
M
GD3035C
--- SGD 2,270.51
N
GD3100DS4
--- SGD 5,575.92
M
GD3035D
--- SGD 2,270.51
N
GD3100S4
--- SGD 5,505.02
M
GD3035DA3
----
RFQ
N
GD3100S1
----
RFQ
M
GD3035
--- SGD 905.76
L
GD3040C
--- SGD 2,451.16
L
GD3040D
--- SGD 2,385.96
M
GD3035A3
--- SGD 3,695.90
L
GD3040DV
--- SGD 2,713.35
L
GD3040DA3
--- SGD 4,132.92
L
GD3040DS1
--- SGD 4,939.83
L
GD3040A3S7
--- SGD 5,952.75
L
GD3040DS101
--- SGD 4,658.44

Working Mechanism

  • Eaton GD Series moulded case circuit breakers feature fixed thermal and fixed magnetic trips to protect against faulty currents:

Fixed Thermal Trips

  • The thermal trip consists of a bimetallic strip which gets heated and bends when an overcurrent passes through the conductors, which opens the contacts and interrupts the current flow.

Fixed Magnetic Trips

  • The magnetic trip has an electromagnetic component that detects the presence of short circuits in a circuit.
  • As the current rises, a magnetic field is generated that trips the breaker and causes the contacts to open and stop the current flow.

Features

  • These units feature a fixed thermal and fixed magnetic trip unit to avoid nuisance tripping in mild current fluctuation but are highly sensitive to heavy inrush current, thus producing both instantaneous and time-delayed current limiting protection.
  • They have a compact, space-saving design that provides installation in tight spaces and allows for high-speed blow-open action, resulting in superior performance.
  • They are integrated with line and load side terminals for easy installation with panelboards and load centres.
  • These MCCBs also include a toggle and a mechanical latching mechanism that ensures the circuit breaker remains in the tripped position until it is manually reset.

Standards and Approvals

  • UL

Frequently Asked Questions

What is the advantage of moulded cases?

Moulded cases hold current-carrying components, trip devices and mechanisms integrated into one unit.

What is the purpose of a G-frame?

A G-frame is a modular design that provides a versatile and flexible platform to accommodate low-voltage circuit breakers. They also protect electrical systems from damage caused by overloads and short circuits, as well as mechanical stress.

What is the purpose of a toggle?

These circuit breakers come with an integrated over-centre toggle for visual indication of tripped status.

We are here to help!

Looking for a part not listed here?