EATON xEffect Series FRCmM-NA Residual Current Circuit Breakers | Raptor Supplies Singapore

EATON xEffect Series FRCmM-NA Residual Current Circuit Breakers

Eaton xEffect FRCmM-NA residual current circuit breakers (RCCBs) are ideal for sensing and disconnecting any low voltage (uneven current) circuit whenever a fault occurs. They are used in offices, industrial layouts and low-voltage applications.

Filter
StyleModelPrice (inc. GST)
A
167102
- SGD 3,613.26
B
167701
- SGD 3,492.23
C
167698
- SGD 2,039.12
B
167125
- SGD 4,085.25
B
167699
- SGD 3,492.23
D
167693
- SGD 2,491.03
E
167695
--
RFQ
B
167709
- SGD 3,778.10
C
167696
- SGD 2,039.12
C
167697
- SGD 2,039.12
C
167124
- SGD 2,039.12
B
167700
- SGD 3,492.23
B
167710
--
RFQ
B
167703
- SGD 3,778.10
B
167704
- SGD 3,778.10
B
167705
- SGD 3,492.23
B
167708
- SGD 3,778.10
B
167707
- SGD 3,492.23
B
167706
- SGD 3,492.23
F
167694
- SGD 1,927.34
G
167120
- SGD 1,753.26
B
167110
- SGD 4,153.22
C
167116
--
RFQ
B
167104
--
RFQ
B
167106
- SGD 4,419.66
H
167103
- SGD 3,492.23
B
167111
- SGD 3,778.10
I
167107
- SGD 3,390.54
J
167109
--
RFQ
C
167114
- SGD 1,859.90
K
167115
- SGD 1,927.34
C
167122
- SGD 2,039.12
C
167117
- SGD 2,039.12
C
167123
--
RFQ
B
167112
- SGD 3,778.10
C
167113
- SGD 1,927.34
C
167118
--
RFQ
L
167108
- SGD 3,492.23
M
167121
- SGD 1,927.34
N
167119
- SGD 2,054.71
B
167702
- SGD 3,786.25

Working Mechanism

  • During an earth fault, the residual current circuit breaker continuously detects and contrasts any differences in the current between the live and neutral wires (residual current value).
  • The residual current circuit breaker will trip if there is even a slight difference in the numbers, cutting off the circuit.

Features

  • Eaton xEffect FRCmM-NA RCCBs feature Type A and Type G/A capable of sensing residual pulsating DC offering surge current-proof of 250A and 3kA respectively.
  • They come with a unique test button 'T' to automatically test the function of residual current circuit breakers (RCCB) themselves.
  • These RCCBs devices further feature independent line voltage tripping and operation temperature range of -25 to 40 degrees C.
  • They offer delayed tripping suitable with conventional fluorescent tubes, irrespective of whether electronic ballast is present or not.
  • These circuit breakers provide a tripping indicator and a contact position indicator for additional safety.

Standards and Approvals

  • IEC
  • EN 61008
  • UL

Frequently Asked Questions

What is the rated short circuit capacity of Eaton xEffect FRCmM-NA RCCBs?

5kA (according to CSA)

What is the rated tripping current of these residual current breakers?

30 / 300mA

How do we connect an FRCmM-NA residual current device?

  • RCCB is connected parallel to the miniature circuit breaker (MCB) into the distribution boards.
  • The phase is connected in parallel with the MCB and the neutral connection is done with neutral lines.

We are here to help!