BUSSMANN KLM-30 Fast Acting Fuse, 30 A, Non Indicating, 600 VAC/ADC | AA9FFU 1CW73

BUSSMANN KLM-30 Fast Acting Fuse, 30 A, Non Indicating, 600 VAC/ADC

Item: AA9FFU Model: KLM-30Cross Ref: 1CW73
In Stock : 97 Units

Get it by Friday, Apr 11

SGD 25.41 /unit (inc. GST)
Add To Cart
Request a Quote

Payment

Delivery

Product Specifications:

ItemFast Acting Midget Fuse
Amps30A
Body MaterialMelamine
Body StyleCartridge Fuses
ClassMidget
Compatible WithBMM, C2617, C5268, CHM, HEB, HPG, HPS Series
Dc Voltage600V DC
Diameter0.406"
ElementSingle
Fuse Block DesignNon Rejection
Fuse Protection TypeFast Blow
Indicating / NonindicatingNon Indicating
Interrupt Rating100 kA at 600V AC, 50 kA at 600V DC
Length1 1/2"
Overall Diameter13/32"
Rejection / NonrejectionNon Rejection
SeriesBussmann KLM, Littelfuse KLKD, Mersen ATM Series , KLM Series
Visual IndicationNon Indicating
Voltage600V AC/600V DC

Shipping Info:

Ship weight (kg) 0.08
HS code8536100040
Country of OriginMX

Product Details:

Bussmann KLM-30 fuse is a current-limiting, fast-acting fuse that protects electrical circuits and components from overcurrent conditions. It is useful in the power generation, automotive, telecommunications and oil & gas industries.

Working Mechanism:

  • When the current passing through a non-indicating fuse exceeds its rated value, the fuse element within the fuse body melts (breaks).
  • This melting interrupts the circuit and prevents further current flow.
  • This action helps to safeguard electrical components and systems from damage caused by excessive current levels.

Frequently Asked Questions:

Q. What is the I2t rating of a fuse?

A. The I2t rating represents the energy-carrying capacity of a fuse. It is a measure of how much energy can pass through the fuse before it blows.

Q. What is meant by the time-current characteristics of a fuse?

A. The time-current characteristics of a fuse refer to how the fuse responds to overcurrent conditions in terms of time.

Q. What are one-time fuses and time-delay fuses?

A. One-time fuses, also called non-renewable fuses, are designed to operate only once and must be replaced after tripping. Time-delay fuses, on the other hand, have a delayed response to overcurrent, allowing temporary surges to pass without tripping.

Product Variants

ProductModelAc Voltage RatingBody StyleCurrent RatingDc Voltage RatingDiameterFuse AmpsFuse Size / GroupInterrupt RatingPrice
BUSSMANN KLM-10 Fast Acting Fuse, 10 A, Non Indicating, 600 VAC/ADC | AA9FFN 1CW64
KLM-10-Cylindrical--13/32"10-10kA at 600 VAC/DC SGD 25.41
BUSSMANN KLM-15 Fast Acting Fuse, 15 A, Non Indicating, 600 VAC/ADC | AA9FFP 1CW65
KLM-15-Cylindrical--13/32"15-10kA at 600 VAC/DC SGD 25.41
BUSSMANN KLM-2 Fast Acting Fuse, 2 A, Non Indicating, 500 VAC/500 VDC | AA9FFQ 1CW66
KLM-2-Cylindrical--13/32"2-10kA at 500 VAC/DC SGD 25.41
BUSSMANN KLM-20 Fast Acting Fuse, 20 A, Non Indicating, 500 VAC | AA9FFR 1CW68
KLM-20-Cylindrical--13/32"20-10kA at 500VAC, 10kA at 600VDC SGD 24.74
BUSSMANN KLM-25 Fast Acting Fuse, 25 A, Non Indicating, 500 VAC | AA9FFT 1CW69
KLM-25-Cylindrical--13/32"25-10kA at 500VAC, 10kA at 600VDC SGD 25.41
BUSSMANN KLM-5 Fast Acting Fuse, 5 A, Non Indicating, 500 VAC/500 VDC | AA9FFV 1CW75
KLM-5-Cylindrical--13/32"5-10kA at 500 VAC/DC SGD 25.41
BUSSMANN KLM-6 Fast Acting Fuse, 6 A, Non Indicating, 600 VAC/ADC | AA9FFW 1CW76
KLM-6-Cylindrical--13/32"6-10kA at 600 VAC/DC SGD 25.41

Explore Products

Contact us

Contact your account manager right away to get personal advice.
We're available Monday through Friday, from 09:00 until 17:00.

BUSSMANN KLM-30 Fast Acting Fuse, 30 A, Non Indicating, 600 VAC/ADC
SGD 25.41 /unit (inc. GST)