Differential Pressure Gauges | Raptor Supplies Singapore

DWYER INSTRUMENTS Differential Pressure Gauges

Dwyer Instruments differential pressure gauges are visual indicators designed to measure and illustrate the difference between two pressure points within a process system. These gauges offer a full-scale accuracy of 2% while measuring positive, negative or differential pressure values. The unique design of these units is capable of resisting shock, vibration and over-pressures with no manometer fluid to evaporate and freeze, as well as cause toxic or levelling problems. They are also suitable for checking the gas-air ratio control and monitoring blood and respiratory pressures in medical care equipment. Choose from a range of these differential pressure gauges available in 4 inch and 4-1/2 inch dial sizes on Raptor Supplies.

Filter

Dwyer Instruments pressure gauges are ideal for measuring & visually indicating positive & negative pressure and pressure differentials of air or non-corrosive gasses. Their unique design resists... Read More

DWYER INSTRUMENTS -

2000 Series Magnehelic Differential Pressure Gages

StyleModelAccuracyItemPressure RangePrice (inc. GST)
A2000-100CM-Gauge- SGD 166.61
B2000-80CM-Gauge- SGD 166.61
B2000-30CM-Gauge- SGD 169.95
B2001-ASF-Gauge- SGD 194.11
A2003-ASF-Gauge- SGD 195.78
A2001-LT-Gauge- SGD 196.78
A2002-ASF-Gauge- SGD 193.15
A2202-Gauge- SGD 174.13
C2010-LT-Gage- SGD 201.16
A2003-LT-Gage- SGD 201.16
A2300-10CM-Gauge- SGD 201.02
A2000-200CM-Gauge- SGD 179.94
B2000-125PA-Gauge- SGD 154.14
B2000-1.5KPA-Gauge- SGD 158.75
D2020-/+ 2%Differential Pressure Gauge0 to 20" wc SGD 188.11
E2040-/+ 2%Differential Pressure Gauge0 to 40" wc SGD 205.93
F2030-/+ 2%Differential Pressure Gauge0 to 30" wc SGD 157.83
G2000-0-/+ 2%Differential Pressure Gauge0 to 0.5" wc SGD 182.64
H2008-/+ 2%Differential Pressure Gauge0 to 8" wc SGD 185.36
I2004-/+ 2%Differential Pressure Gauge0 to 4" wc SGD 185.92
J2010-AV-/+ 2%Differential Pressure Gauge0 to 10" wc SGD 207.94
K2001-/+ 2%Differential Pressure Gauge0 to 1" wc SGD 162.62
L2002-/+ 2%Differential Pressure Gauge0 to 2" wc SGD 196.64
M2005-/+ 2%Differential Pressure Gauge0 to 5" wc SGD 193.70
N2010-/+ 2%Differential Pressure Gauge0 to 10" wc SGD 128.29
DWYER INSTRUMENTS -

Differential Pressure Gage Range 0-35 Ft, 4635B

ModelItemPrice (inc. GST)
4635BCP3YHH SGD 2417.18

Features

  • Dwyer Series 2000 Magnehelic differential pressure gages uses frictionless Magnehelic gage movement for accurate measurements without requiring any power at low costs.
  • They are used during monitoring of filter, air velocity, blower vacuum, fan pressure & area pressures.
  • These Magnehilic gauges have die-cast aluminium casing and bezel & acrylic covering with IP67 rating.
  • They have 2 pairs of 1/8 inch female NPT connections (1 pair each of high and low-pressure taps).
  • Their break-resistant plastic face with precision litho-printed scale provides clear reading visibility even from a distance.
  • Their blowout plug vents the interior in case of overpressures.
  • Dwyer Series A3000 Photohelic switches / gauges combine the benefits of pressure switches to the Magnehilic gauges and are ideal for air conditioning systems, clean rooms & fume exhaust systems.
  • These Dwyer pressure gauges are equipped with two phototransistor-actuated DPDT relays for low & high-pressure limit control using knobs located on the gauge face.
  • Gauge reading of these switches remains unaffected by switch operation, even without electrical power.
  • These switches / gauges accept 10A current at 28VDC or 120 / 240VAC supply through their screw terminals.
  • Their glass-epoxy printed circuit boards & plastic enclosure protect the electrical circuits & ensure durability.
  • They feature switch set pointers that display the switch set point settings at all times and their spring-loaded friction clutch protects the set point mechanism from operator damages.

Working Mechanism

  • For Dwyer Series 2000 Magnehelic differential pressure gages, set the gauge pointer on the zero mark by adjusting the screw at the bottom of the cover after the high & low-pressure taps are opened to the atmosphere.
  • During positive pressure, connect tubing from the source to one of the high-pressure ports and then vent the low-pressure ports to the atmosphere.
  • During negative pressure, connect the vacuum tubing source to the low-pressure port & then vent the high-pressure ports to the atmosphere.
  • Durng differential pressure, connect the greater pressure source to high-pressure port and lower pressure source to low-pressure port.
  • After ensuring that unused ports are plugged, the units show the correct pressure.

Standards and Approvals

  • CE
  • RoHS
  • CSA
  • UL

Frequently Asked Questions

Do these Dwyer pressure gauges require maintenance?

These Dwyer pressure gauges require no lubrication or periodic servicing. Users just need to keep the case exterior & cover clean and disconnect the pressure lines sometimes to vent gauges to the atmosphere for re-zeroing.

How to install Dwyer Series 2000 Magnehelic differential pressure gages?

  • Select a mounting position that is free from excess vibration & direct sunlight and temperature is below 140 degrees F (60 degrees C).
  • Longer tubing lengths may not affect the accuracy but can increase the response time.
  • Use supplied mounting hardware / machine screws to secure the gauge in place. Users need to buy an optional A-610 pipe mounting kit for mounting the unit on a pipe.

What accessories are compatible with these Dwyer pressure gauges?

These Dwyer pressure gauges are compatible with differential pressure switches that control the flow rate / volume passing through the system. They can also accommodate tubing & mounting adapters for quick connections & installations.

We are here to help!

Looking for a part not listed here?